florida cleanroom systems 116
image

"Velocity™" Modular Cleanroom Wall Systems
The Full View Cleanroom Environment

florida cleanroom systems 092    "Velocity™" modular cleanroom wall systems are available in two styles, our "V-2.625" non thermal break system for installation into ambient air  conditioned spaces and our V-3.142" thermal break system for R-12 performance in non air conditioned spaces. 

  "Velocity™" modular cleanroom systems sales information may be found in our PDF downloads page with technical drawings and details available on our DWG downloads page. A gallery of completed projects may be viewed in our projects section.  
         

Florida Cleanroom Systems 6.1
shadow
"Velocity™" V-2.625 Cleanroom Wall Systems

Advantages of "Velocity™" V-2.625 Cleanroom Wall Systems:
  • Designed and Engineered for DIY installations, with complete assembly drawings, shop drawings and installation instructions. Signed and sealed drawings available at additional cost for building department reviews. 
  • Fully Powdercoated Frame and Door Components, will resist scratches, impact, cleaning chemicals, and abrasions better than simple anodized aluminum systems. Longer lifecycle, higher value added to your facility.
  • PVC Double Gasketed Doors, Windows, and Panel Inserts, minimize air leakage, pressurization drop, and cross contamination between cleanroom zones. PVC gaskets resistant to fungal or bacteria growth. 
  • Fully Interchangeable Panel Inserts, 1/4" tempered safety glass, 1/4" Acrylic, 13/16" .025 Aluminum with EPS or aluminum honeycomb cores. Allows for repositioning of solid, glass, door or pass through device panels of like sizes to accommodate changes in process flow or equipment layouts.
  • Flush One Side or Coved Sill Insert Trim, offers a truly flush interior for lower maintenance, less bioburden or particulate entrapment areas.
  • Continuous Horizontal Ceiling Frames, for minimum gaps when installing cleanroom ceiling systems. No need for unsightly caulking when ceiling system perimeter channels roll over horizontal post systems.
  • 4" to 10" Continuous Horizontal Floor Base Frames, allow for installation of medical grade vinyl or epoxy cleanroom flooring systems with cove base without unsightly gaps when rolling over horizontal post systems.
  • 4" to 10" Wide x 2.525" Thick Hollow Vertical Utility Chases, flush with base and ceiling frame members, accommodates various code compliant electrical, process piping, sanitary plumbing, network and low voltage systems without the need for unsightly surface mounting techniques. Offers a truly flush interior for lower maintenance, less bioburden or particulate entrapment areas.
  • Clear View Floor to Ceiling 1/4" Tempered Safety Glass, or 1/4" acrylic up to 10' high for maximized view of process and operational protocols. Allows for supervision of cleanroom processes and personnel without the need to enter the cleanroom environment.
  • Window Systems up to 120" high without the need for horizontal post interruptions for gallery type views of cleanroom interiors. Offers  uninterrupted views for clients, supervisors, or inspectors.
  • Interior or Exterior Low Level Return Plenums, allow for correct unidirectional air flow patterns and air changes per cleanroom zone.  
  • Manufactured to ISO, cGMP, FDA, USP-797 Regulatory Standards, to comply with ISO 14644-4 design and construction of cleanroom facilities.


florida cleanroom system 117
shadow
"Velocity™" V-3.125 Cleanroom Wall Systems

Advantages of "Velocity™" V-3.125 Cleanroom Wall Systems:
  • Designed and Engineered for DIY installations, with complete assembly drawings, shop drawings and installation instructions. Signed and sealed drawings available at additional cost for building department reviews. 
  • Fully Powdercoated Frame and Door Components, will resist scratches, impact, cleaning chemicals, and abrasions better than simple anodized aluminum systems. Longer lifecycle, higher value added to your facility.
  • PVC Dual Gasketed Doors, Windows, and Panel Inserts, minimize air leakage, pressurization drop, and cross contamination between cleanroom zones. PVC gaskets resistant to fungal or bacteria growth. 
  • Fully Interchangeable 3" Thick Panels,  EPS(Expanded Polystyrene Foam) cores R-12, or aluminum honeycomb core R-6, surface finishes of .025 Aluminum, .020 FRP(Fiberglass reinforced plastic) or .020 HPL(High Pressure Laminated). System allows for repositioning of solid, glass, door or pass through device panels of like sizes to accommodate changes in process flow or equipment layouts.
  • Fully Interchangeable Dual Gasketed Widow Units, with 1/4" tempered safety glass, 1/4" Acrylic, or 13/16" Insulated windows. System allows for repositioning of solid, glass, door or pass through device panels of like sizes to accommodate changes in process flow or equipment layouts.
  •  4" to 10" Wide x 3.125" Thick Hollow Vertical Utility Chases, flush with base and ceiling frame members, accommodates various code compliant electrical, process piping, sanitary plumbing, network and low voltage systems without the need for unsightly surface mounting techniques. Offers a truly flush interior for lower maintenance, less bioburden or particulate entrapment areas.
  • Interior or Exterior Low Level Return Plenums, allow for correct unidirectional air flow patterns and air changes per cleanroom zone.
  • Manufactured to ISO, cGMP, FDA, USP-797 Regulatory Standards, to comply with ISO 14644-4 design and construction of cleanroom facilities.


floridacleanroom systems 2.2

shadow

Florida Cleanroom Systems

Advantages of Florida Cleanroom Systems Modular Designs:

  • Reduced A/E Cost, factory generated shop drawings, details, and engineering calculations greatly reduce architectural and engineering cost associated with designing and engineering from scratch.
  • Reduced Construction Scheduling, time saving fully pre-fabricated and pre-finished wall frames and wall sections allow installation crews to work in 8' to 16' sections versus handling individual 4' panels.
  • Reduced Construction Cost, labor saving fully pre-fabricated and pre-finished wall sections install in 1/3 the time as conventionally constructed wall systems.
  • Reduced Utility Systems Cost, pre-wired modular electrical systems will  greatly reduce the cost when compared to conventional piping field installations of the same electrical components. Modular low voltage wiring systems and cat5 cabling systems along with flexible fire sprinkler systems further reduce field construction time and labor. All systems are fully relocatable with cleanroom structure.
  • Reduced VOC Emissions, Fully pre-finished components reduce VOC emissions within your facility due to no use of adhesives or paints.
  • Reduced Tax Liability, can be considered capital equipment instead of capital improvements; therefore, they can be depreciated at an accelerated rate. .
  • Reduced Safety Cost, modular systems install with 1/3 the labor required by conventional construction. Reducing personnel and associated insurance and safety cost.
  • Reduced Maintenance Cost, antifungal and antimicrobial components reduce the daily cleaning requirements with powdercoated finishes reducing the cost of refinishing systems over time.
  • Reduced Renovation Cost, expanding a modular cleanroom can be easily accomplished by taking off a wall and adding another module. The prefabricated design allows the room to be expanded, relocated, or reconfigured into a different shape or made into multiple smaller rooms.
  • Reduced Lease Termination Cost, modular cleanroom systems cause minimal impact on building systems and structure reducing return to origin cost associated with leased facilities.
  • Reduced Relocation Cost, modular cleanroom systems are typically 95% relocatable when the time comes to relocate to a new facility. You take it with you.
  • Consistent Fit and Finish, high speed manufacturing systems with quality assurance checkpoints assure consistent fit and finish of all components. 
  • CleanBuild Construction, pre-fabricated and pre-finished modular components minimize field cuts and fitting reduces the construction generated particulates normally associated with conventional construction. 


florida cleanroom systems 197
shadow  Additional advantages, architectural details, and engineered drawings   of  "Velocity™" modular cleanroom systems can be further explored via our "Velocity™" downloads located in our PDF downloads section.